2.
BMC Ophthalmol ; 24(1): 172, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627651

RESUMO

PURPOSE: To assess the efficacy and safety of various intraocular lenses (IOLs), including standard monofocal, bifocal, trifocal, extended depth of focus (EDOF), and enhanced monofocal IOLs, post-cataract surgery through a network meta-analysis. METHODS: A systematic search of PubMed, Cochrane Library, and Web of Science was conducted to identify relevant studies from the past 5 years. Parameters such as binocular visual acuities, spectacle independence, contrast sensitivity (CS), and optical quality were used to evaluate efficacy and safety. Data from the selected studies were analyzed using Review Manager 5.4 and STATA 17.0 software. RESULTS: Twenty-eight Randomized Controlled Trials (RCTs) comprising 2465 subjects were included. Trifocal IOLs exhibited superior uncorrected near visual acuity (UNVA) compared to monofocal IOLs (MD: -0.35; 95% CI: -0.48, -0.22). Both trifocal (AcrySof IQ PanOptix IOLs group MD: -0.13; 95% CI: -0.21, -0.06) and EDOF IOLs (MD: -0.13; 95% CI: -0.17, -0.09) showed better uncorrected intermediate visual acuity (UIVA) than monofocal IOLs. Trifocal IOLs ranked highest in spectacle independence at various distances (AT LISAtri 839MP group: SUCRA 97.5% for distance, 80.7% for intermediate; AcrySof IQ PanOptix group: SUCRA 83.0% for near). CONCLUSIONS: For cataract patients who want to treat presbyopia, trifocal IOLs demonstrated better visual acuity and spectacle independence at near distances. Different types of trifocal IOL characteristics differ. EDOF and enhanced monofocal IOLs have improved visual quality at intermediate distances.Therefore, It is very important to select the appropriate IOLs based on the lens characteristics and patient needs.


Assuntos
Catarata , Lentes Intraoculares , Facoemulsificação , Presbiopia , Humanos , Implante de Lente Intraocular , Presbiopia/cirurgia , Refração Ocular , Satisfação do Paciente , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto
3.
Br J Ophthalmol ; 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38604620

RESUMO

AIMS: The aim of this study was to analyse the effective lens position (ELP) in patients with Marfan syndrome (MFS) and ectopia lentis (EL). METHODS: Patients with MFS undergoing lens removal and primary intraocular lens (IOL) implantation were enrolled in the study. The back-calculated ELP was obtained with the vergence formula and compared with the theoretical ELPs. The back-calculated ELP and ELP error were evaluated among demographic and biometric parameters, including axial length (AL), corneal curvature radius (CCR) and white-to-white (WTW). RESULTS: A total of 292 eyes from 200 patients were included. The back-calculated ELP was lower in patients undergoing scleral-fixated IOL than those receiving in-the-bag IOL implantation (4.54 (IQR 3.65-5.20) mm vs 4.98 (IQR 4.56-5.67) mm, p<0.001). The theoretical ELP of the SRK/T formula exhibited the highest accuracy, with no difference from the back-calculated ELP in patients undergoing in-the-bag IOL implantation (5.11 (IQR 4.83-5.65) mm vs 4.98 (IQR 4.56-5.67) mm, p=0.209). The ELP errors demonstrated significant correlations with refraction prediction error (PE): a 1 mm ELP error led to PE of 2.42D (AL<22 mm), 1.47D (22 mm≤AL<26 mm) and 0.54D (AL≥26 mm). Multivariate analysis revealed significant correlations of ELP with AL (b=0.43, p<0.001), CCR (b=-0.85, p<0.001) and WTW (b=0.41, p=0.004). CONCLUSION: This study provides novel insights into the origin of PE in patients with MFS and EL and potentially refines existing formulas.

4.
Front Med (Lausanne) ; 11: 1366576, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38439904

RESUMO

Anterior capsular contraction syndrome (ACCS) is a challenging complication that can occur following phacoemulsification cataract surgery. Characterized by capsular bag wrinkling, intraocular lens (IOL) decentration and tilt, ACCS can have negative effects on visual outcomes and patient satisfaction. This review aims to investigate the pathogenesis, clinical course, influencing factors, and intervention approaches for ACCS after cataract surgery. By understanding the underlying mechanisms and identifying factors that contribute to ACCS, surgeons can enhance their ability to predict and manage this complication. Various intervention strategies are discussed, highlighting their importance in reducing complications and improving surgical outcomes. However, further research is needed to determine optimal prevention and management strategies through long-term follow-up and comparative analyses. Advancements in this field will ultimately lead to improved visual outcomes and optimized cataract surgery for patients.

5.
Korean J Ophthalmol ; 38(2): 129-136, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38414249

RESUMO

PURPOSE: To assess long-term clinical results following bilateral Tecnis Symfony ZXR00 intraocular lens implantation with mini-monovision. METHODS: The medical records of cataract patients who underwent bilateral implantation of ZXR00 with intended mini-monovision (target refraction of -0.3 diopters [D] in dominant eye and -0.6 D in nondominant eye) between April 2019 and March 2021 were assessed. Postoperative uncorrected distance visual acuity (UDVA), corrected distance VA (CDVA), uncorrected intermediate VA (UIVA), uncorrected near VA (UNVA), and rate of spectacle dependence for near distance were investigated at 3 months and 2 years after surgery. RESULTS: This study included 61 patients (122 eyes) with average age of 61.8 ± 7.7 years. At 2 years postoperatively, binocular logarithm of the minimum angle of resolution UDVA, UIVA, UNVA, and CDVA were 0.086 ± 0.094, 0.056 ± 0.041, 0.140 ± 0.045, and 0.012 ± 0.024, respectively. The monocular manifest refraction spherical equivalent was -0.31 ± 0.38 in the dominant eye and -0.53 ± 0.47 in the nondominant eye at 3 months postoperatively, and -0.38 ± 0.43 in the dominant eye and -0.61 ± 0.54 in the nondominant eye at 2 years postoperatively. Eight out of 61 patients (13.1%) needed glasses 3 months after surgery, and nine out of 61 patients (14.8%) needed glasses 2 years after surgery. CONCLUSIONS: The bilateral implantation of ZXR00s with mini-monovision allows for a good VA at wide range of distance from far to near, thereby resulting in high rate of spectacle independence. These results have held up well even after 2 years after surgery.


Assuntos
Lentes Intraoculares , Facoemulsificação , Humanos , Pessoa de Meia-Idade , Idoso , Implante de Lente Intraocular , Visão Monocular , Acuidade Visual , Refração Ocular , Desenho de Prótese , Satisfação do Paciente , Visão Binocular
6.
Front Med (Lausanne) ; 11: 1349496, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38414624

RESUMO

Toric intraocular lenses (IOLs) have been developed to enhance visual acuity impaired by cataracts and correct corneal astigmatism. However, residual astigmatism caused by postoperative rotation of the toric IOL is an important factor affecting visual quality after implantation. To decrease the rotation of the toric IOL, significant advancements have been made in understanding the characteristics of toric IOL rotation, the factors influencing its postoperative rotation, as well as the development of various measurement techniques and interventions to address this issue. It has been established that factors such as the patient's preoperative refractive status, biological parameters, surgical techniques, postoperative care, and long-term management significantly impact the rotational stability of the toric IOL. Clinicians should adopt a personalized approach that considers these factors to minimize the risk of toric IOL rotation and ensure optimal outcomes for each patient. This article reviews the influence of various factors on toric IOL rotational stability. It discusses new challenges that may be encountered to reduce and intervene with rotation after toric IOL implantation in the foreseeable future.

7.
Eur J Ophthalmol ; : 11206721241226743, 2024 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-38233368

RESUMO

PURPOSE: To report three cases of postoperative opacification of sutureless scleral-fixed hydrophilic intraocular lens (FIL SSF IOL, Soleko, Italy) after gas tamponade. Two cases occurred after pars plana vitrectomy and one case after Descemet membrane endothelial keratoplasty. CASE REPORT: Two diabetic patients underwent a FIL SSF IOL implantation after posterior capsular rupture during cataract surgery. Rhegmatogenous retinal detachment (RRD) was observed in one patient during the initial surgery. A second patient developed a RRD five months after surgery. Both RRDs were treated with pars plana vitrectomy and perfluoroethane (C2F6) gas tamponade. A few days after the surgery, C2F6 was observed in the anterior chamber of both patients. Two months after gas tamponade, opacification of the anterior surface of the IOL was observed. The third patient was a 74-year-old woman, who underwent a combined Descemet membrane endothelial keratoplasty (DMEK) and FIL SSF IOL implantation. Two rebubblings with sulfur hexafluoride (SF6) retreatments were required due to corneal graft detachment. One month later, an opacification of the anterior surface of the IOL was observed. Explantation with implantation of iris-claw IOL was decided, which resulted in an improvement of BVCA. Analysis of the IOL showed a positive Von Kossa staining, indicating calcification of the IOL. We performed a review of all the cases of FIL SSF IOL implantation in our centers. The overall rate of FIL SSF IOL opacification was 2.1% (3/140). Amongst patients treated with gas tamponade, the rate of opacification was 27.3% (3/11). Although FIL SSF IOL implantation appears to be an effective option for the treatment of aphakia, caution should be exercised regarding the risk of opacification following gas tamponade, especially since these patients are at risk of retinal detachment.

8.
Curr Eye Res ; 49(2): 207-213, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37933837

RESUMO

PURPOSE: To learn whether contrast adaptation, induced by positive spherical defocus, is compromised by macular disorders such as age-related macular degeneration (AMD) or epiretinal membranes (ERM) and to gain further insight in the functionality of the pathological macula and the level of "functional reserve" often postulated for the indication of presbyopia correcting IOLs. METHODS: In a pilot study, patients with macular disorders, AMD and ERM, (n = 10) and healthy volunteers (n = 10) were tested to quantify contrast adaption after +4 D defocus for 10 min, by performing an interocular contrast matching task. Subjects manually adjusted the perceived contrast of the test patch as seen by the test eye to match to the contrast of a target patch with a fixed Michelson contrast of 0.2 as seen by the contralateral untreated eye. RESULTS: Patients with macular disorders subjectively matched the 0.2 target contrast with a contrast of 0.24 ± 0.06 (mean ± SD) before adaptation and with a contrast of 0.19 ± 0.04 after adaptation (p < 0.05). Accordingly, patients with macular disorders showed an induced contrast gain by adaptation of 0.05 (27%), which was not different from the control group, which showed an induced contrast gain by adaptation of 0.06 (35%). CONCLUSION: Patients with mild and moderate macular disorders, such as AMD and ERM, show an induced contrast adaptation, i.e. a gain in contrast sensitivity, at 3.2 cpd, which is not different in level from the induced contrast adaptation in healthy subjects. Macular disorders do not prevent adaptation of the patient's visual system to low contrast or blurred retinal images. Therefore, the implantation of presbyopia correcting IOLs is not a strict exclusion criterion for these patients, but the progressive nature of the macular disorder must be taken into account.


Assuntos
Membrana Epirretiniana , Lentes Intraoculares , Degeneração Macular , Presbiopia , Doenças Retinianas , Humanos , Acuidade Visual , Projetos Piloto , Degeneração Macular/diagnóstico
9.
Eur J Ophthalmol ; 34(2): 432-439, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37461240

RESUMO

PURPOSE: To report the causes of pseudophakic intraocular lens (IOL) explantation in Spain over a 20 year period. METHODS: Multicenter observational prospective study of a consecutive series of cases corresponding to pseudophakic intraocular lenses explantations performed in 22 Spanish clinical centres from 2002 to 2021, within a national clinical research network. The clinical data of all IOL explantation patients was evaluated, and the different causes for IOL explantation were systematically analyzed. RESULTS: From a total of 1013 pseudophakic explantations, 919 cases were included in this investigation. The mean age of the patients at the time of explantation was 66.3 years, and 142 (15.45%) were women. Over the 20 years of the study, the five main reasons for explanting lenses in the last 20 years in Spain according to the Iberia RETICS database were: dislocation / decentration / misalignment (43.08%), bullous keratopathy (16.79%), neuroadaptation failure (13.85%), IOL opacification (9.71%), refractive surprise (6.87%). Other causes, less frequent, were uveitis / endophthalmitis / infection with 39 cases (4.25%); IOL substitution for reasons other than multifocal IOL neuroadaptation failure 3 cases (0.33%); and other causes, 47 cases (5.13%). Hydrophobic lenses were the most frequently explanted with a ratio of 47.1%. CONCLUSIONS: Over the 20 years of the study, the five main reasons for explanting lenses in the last 20 years in Spain according to the Iberia RETICS database were: dislocation / decentration / misalignment, bullous keratopathy, neuroadaptation failure, IOL opacification, and refractive surprise.


Assuntos
Lentes Intraoculares , Humanos , Feminino , Idoso , Masculino , Espanha/epidemiologia , Estudos Prospectivos , Lentes Intraoculares/efeitos adversos , Complicações Pós-Operatórias/etiologia , Acuidade Visual
10.
Surv Ophthalmol ; 69(1): 140-159, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37640272

RESUMO

A growing number of patients with prior refractive surgery are now presenting for cataract surgery. Surgeons face a number of unique challenges in this patient population that tends to be highly motivated to retain or regain functional uncorrected acuity postoperatively. Primary challenges include recognition of the specific type of prior surgery, use of appropriate intraocular lens (IOL) power calculation formulas, matching IOL style with spherical aberration profile, the recognition of corneal imaging patterns that are and are not compatible with toric and/or presbyopia-correcting lens implantation, and surgical technique modifications, which are particularly relevant in eyes with prior radial keratotomy or phakic IOL implantation. Despite advancements in IOL power formulae, corneal imaging, and IOL options that have improved our ability to achieve targeted postoperative refractive outcomes, accuracy and predictability remain inferior to eyes that undergo cataract surgery without a history of corneal refractive surgery. Thus, preoperative evaluation of patients who will and will not be candidates for postoperative refractive surgical enhancements is also paramount. We provide an overview of the specific challenges in this population and offer evidence-based strategies and considerations for optimizing surgical outcomes.


Assuntos
Astigmatismo , Extração de Catarata , Catarata , Lentes Intraoculares , Facoemulsificação , Humanos , Acuidade Visual , Satisfação do Paciente , Astigmatismo/cirurgia , Refração Ocular
11.
Clin Ophthalmol ; 17: 3915-3923, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38143560

RESUMO

Purpose: The optical function of a novel refractive-diffractive trifocal intraocular lens (IOL) was tested in vitro to provide preclinical metrics that predict postoperative performance and may guide patient selection. Methods: Fundamental optical characteristics of a trifocal hydrophobic-acrylic IOL with a C-loop haptic configuration (AT ELANA 841P, Carl Zeiss Meditec) were assessed using a fully automated optical test device under both monochromatic and polychromatic conditions combined with increased or compensated spherical aberration (SA). The area under the modulation transfer function (MTFa) was calculated across a defocus range from +1D to -3.5D and used to simulate visual acuity (VA). A polychromatic point spread function (PSF) was employed to assess the light distribution and identify photic phenomena. Results: The highest MTFa values were obtained under monochromatic conditions using an SA-neutral corneal model. Nevertheless, after introducing SA and polychromatic light, the IOL performance remained good. Simulated VA values were 0.00 logMAR for distance, 0.1 logMAR at 100 cm, and progressively improving to 0.05 logMAR at 40 cm from the intermediate point. The light-spread analysis confirmed halos around the PSF center, which is a characteristic of trifocal technology. Conclusion: AT ELANA 841P demonstrated good optical performance across various distances, independently of spectral and SA conditions, resulting in good simulated VA. Although light spread resembles standard trifocal IOLs, clinical studies are essential to confirm these laboratory results.

12.
BMC Ophthalmol ; 23(1): 516, 2023 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-38114950

RESUMO

BACKGROUND: Here we described a new threading technique for the universal fixation of any posterior chamber intraocular lens (IOL). METHODS: Twenty-seven eyes of 27 patients whose surgery done by Surgeon A with the needle-guided method or the suture needle retrograde threading (SNRT) method for intrascleral IOL fixation were enrolled in the first group. Thirty-four eyes of 34 patients whose surgery done by Surgeon A, Surgeon B or Surgeon C with the SNRT method for intrascleral IOL fixation were grouped into three sub-groups by surgeon. Information regarding age, sex, best-available visual acuity (BCVA), intraocular pressure (IOP), past ophthalmological history, threading time (from puncturing to externalizing suture) and complications during and after the surgery were gathered. RESULTS: The analysis showed that the threading time was less in the SNRT group than needle-guided group by Surgeon A. There was one eye with suture needle slipping from the guide needle when guiding out of the eye. The threading procedure was completed one time without suture ruptures or loop slippage in the SNRT group operated by Surgeon A. And using the SNRT method, Surgeon A, Surgeon B, and Surgeon C did not show any significant difference in threading time. No complications (e.g., vitreous hemorrhage, hyphemia, retinal detachment, suprachoroidal hemorrhage, or hypotony) were observed during surgery or postoperatively in all cases. No leakage occurred at the site of the puncture after the operation. CONCLUSIONS: The described technique appears to be a safe, simple, easy-to-learn, and universal surgical method, which is suitable for various types of IOLs.


Assuntos
Implante de Lente Intraocular , Lentes Intraoculares , Humanos , Implante de Lente Intraocular/métodos , Esclera/cirurgia , Olho Artificial , Técnicas de Sutura , Suturas , Estudos Retrospectivos , Complicações Pós-Operatórias/cirurgia
13.
Int J Mol Sci ; 24(21)2023 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-37958583

RESUMO

The landscape of ophthalmology is undergoing significant transformations, driven by technological advancements and innovations in materials science. One of the advancements in this evolution is the application of nanoporous materials, endowed with unique physicochemical properties ideal for a variety of ophthalmological applications. Characterized by their high surface area, tunable porosity, and functional versatility, these materials have the potential to improve drug delivery systems and ocular devices. This review, anchored by a comprehensive literature focusing on studies published within the last five years, examines the applications of nanoporous materials in ocular drug delivery systems (DDS), contact lenses, and intraocular lenses. By consolidating the most current research, this review aims to serve as a resource for clinicians, researchers, and material scientists engaged in the rapidly evolving field of ophthalmology.


Assuntos
Lentes de Contato , Nanoporos , Sistemas de Liberação de Medicamentos , Olho , Administração Oftálmica
14.
BMC Ophthalmol ; 23(1): 483, 2023 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-38007433

RESUMO

Fuchs endothelial corneal dystrophy (FECD) is the leading indication for EK and may coexist with cataract and presbyopia. Notably, the outcomes of phacoemulsification in FECD patients are not as favorable as those in eyes without this condition. Historically, only monofocal intraocular lenses (IOLs) were recommended for these patients. However, recent reports have described the implantation of Premium-IOLs (such as Multifocal IOLs, Enhanced Depth of Focus IOLs, and Toric IOLs) in FECD eyes undergoing cataract surgery and Descemet membrane endothelial keratoplasty (DMEK). While the results are encouraging, they are not as optimal as those from unoperated eyes, especially when comparing simultaneous procedures to sequential ones. It's advised to perform the DMEK first to improve the accuracy of IOL calculations. Still, even successfully operated eyes may experience secondary graft failure or graft rejection after DMEK. The success rate of a secondary DMEK is typically lower than that of the initial procedure. Furthermore, if the postoperative thickness after DMEK is less than anticipated, laser enhancements might not be an option. There's a pressing need for more controlled and randomized clinical trials to ascertain the safety and effectiveness of Premium-IOLs for FECD eyes. This narrative review aims to collate evidence on the use of Premium IOL technologies in eyes receiving EK and to underscore key points for surgeons performing EK combined with cataract surgery.


Assuntos
Catarata , Transplante de Córnea , Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior , Distrofia Endotelial de Fuchs , Lentes Intraoculares , Presbiopia , Humanos , Implante de Lente Intraocular/métodos , Lâmina Limitante Posterior , Presbiopia/cirurgia , Acuidade Visual , Transplante de Córnea/métodos , Distrofia Endotelial de Fuchs/cirurgia , Catarata/complicações , Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior/métodos , Estudos Retrospectivos
15.
Case Rep Ophthalmol ; 14(1): 540-545, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37901624

RESUMO

Negative dysphotopsia (ND) refers to the subjective perception of an arc-shaped darkness or shadow in the temporal field of vision. This condition occurs after uneventful cataract surgery with an in-the-bag intraocular lens (IOL). To address this issue, supplementary implantation of conventional three-piece IOLs in the sulcus or dedicated supplementary Rayner Sulcoflex® IOL have been used successfully. The aim of this retrospective case series was to assess the effectiveness of resolving ND using a supplementary 1stQ AddOn® (Medicontur) IOL. The 1stQ AddOn® has a different design and optic size compared to the Rayner Sulcoflex®. Patients experiencing severe and persistent ND underwent supplementary implantation of the 1stQ AddOn® IOL. The primary outcome measure was the resolution of dysphotopsia. Nine eyes received the 1stQ AddOn® IOL, with complete symptom resolution observed in 6 eyes, partial improvement in 1 eye, and no change in 2 eyes. This indicates that supplementary implantation of the 1stQ AddOn® IOL can effectively and safely treat ND, performing equally well as the Rayner Sulcoflex®. The positive impact of sulcus-fixated supplementary IOLs seems to be related to the interaction between the central optic and the pupil margin.

16.
Br J Ophthalmol ; 2023 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-37845000

RESUMO

PURPOSE: Evaluate whether the axial length of the fellow eye can be used to calculate the intraocular lens (IOL) in eyes with retinal detachment. DESIGN: Retrospective, consecutive case series. METHODS: Our study was conducted at the Goethe University and included patients who underwent silicone oil (SO) removal combined with phacoemulsification and IOL implantation. Preoperative examinations included biometry (IOLMaster 700, Carl Zeiss). We measured axial length (AL) of operated eye (OE) or fellow eye (FE) and compared mean prediction error and mean and median absolute prediction error (MedAE) using four formulas and AL of the OE (Barrett Universal II (BUII)-OE). Additionally, we compared the number of eyes within ±0.50, ±1.00 and ±2.00 dioptre (D) from target refraction. RESULTS: In total, 77 eyes of 77 patients met our inclusion criteria. MedAE was lowest for the BUII-OE (0.42 D) compared with Kane-FE (1.08 D), BUII-FE (1.02 D) and Radial Basis Function 3.0 (RBF3.0)-FE (1.03 D). This was highly significant (p<0.001). The same accounts for the number of eyes within ±0.50 D of the target refraction with the BUII-OE (44 eyes, 57%) outperforming the RBF3.0-FE (20 eyes, 25.9%), Kane-FE and BUII-FE formula (21 eyes, 27.2%) each. CONCLUSION: Our results show a statistically and clinically highly relevant reduction of IOL power predictability when using the AL of the FE for IOL calculation. Using the AL of the SO filled eye after initial vitrectomy results in significantly better postoperative refractive results. A two-step procedure using the AL of the OE after reattachment of the retina is highly recommended.

17.
J. optom. (Internet) ; 16(3): 236-243, July - September 2023. ilus, graf, tab
Artigo em Inglês | IBECS | ID: ibc-222233

RESUMO

Several clinical techniques have been described to evaluate visual performance and optical quality with intraocular lenses (IOL). However, subjective refraction remains one of the most important methods for assessing post-surgery results, taking decisions about retreatments, advanced spectacle prescription and the refinement of the constant for the formula used in the IOL power calculation. Beyond clinical refraction, defocus curve measurement has been described as a complementary tool for assessing visual performance and taking clinical decisions. However, to date, there are no clinical guidelines or evidence-based protocols published in the scientific literature recommended for pseudophakic patients implanted with either monofocal or multifocal IOLs. This narrative review highlights the importance of clinical refraction in pseudophakic eyes, its utility in the decision of different types of IOL implantation, and describes a clinical refraction protocol for eyes implanted with monofocal and multifocal IOLs. (AU)


Assuntos
Catarata , Refração Ocular , Lentes Intraoculares Multifocais , Cirurgia Geral , Guias de Prática Clínica como Assunto , Retratamento
18.
Korean J Ophthalmol ; 37(4): 322-327, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37563972

RESUMO

PURPOSE: To investigate the refractive accuracy of intraocular lens (IOL) power calculation for biometric formulas in phacovitrectomy. METHODS: This retrospective study included 357 eyes of 357 patients who underwent phacovitrectomy using four commonly available IOL power formulas: Hoffer Q (87 eyes), Holladay 1 (78 eyes), Holladay 2 (91 eyes), and SRK/T (101 eyes). The mean refractive error (ME) and the mean absolute refractive error (MAE) were calculated based on the predicted postoperative refraction error, and they were compared using analysis of variance test. Subjects were divided into high myopic eyes (axial length, ≥26 mm) and nonhigh myopic eyes (axial length, <26 mm). RESULTS: The ME and the MAE after phacovitrectomy did not show a significant difference among the four IOL power formulas (p = 0.546 and p = 0.495, respectively). There was no significant statistical difference in formulas when the eyes were grouped into high myopia and nonhigh myopia (ME: p = 0.526 and p = 0.482, respectively; MAE: p = 0.715 and p = 0.627, respectively). The ME showed myopic shift in all formulas regardless of IOL formula used. The ME showed greater myopic shift in high myopia group than nonhigh myopia group in all formulas. CONCLUSIONS: Our study did not find evidence for superiority of any formula in phacovitrectomy. However, in phacovitrectomy, possible myopic shift should be considered for IOL power calculation. Especially, in phacovitrecotmy in patients with high myopia, more myopic shift should be considered when selecting IOL.


Assuntos
Lentes Intraoculares , Miopia , Facoemulsificação , Erros de Refração , Humanos , Implante de Lente Intraocular , Estudos Retrospectivos , Refração Ocular , Miopia/complicações , Miopia/diagnóstico , Miopia/cirurgia , Biometria , Comprimento Axial do Olho
19.
Int J Ophthalmol ; 16(8): 1237-1242, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37602355

RESUMO

AIM: To assess the performance of a bespoke software for automated counting of intraocular lens (IOL) glistenings in slit-lamp images. METHODS: IOL glistenings from slit-lamp-derived digital images were counted manually and automatically by the bespoke software. The images of one randomly selected eye from each of 34 participants were used as a training set to determine the threshold setting that gave the best agreement between manual and automatic grading. A second set of 63 images, selected using randomised stratified sampling from 290 images, were used for software validation. The images were obtained using a previously described protocol. Software-derived automated glistenings counts were compared to manual counts produced by three ophthalmologists. RESULTS: A threshold value of 140 was determined that minimised the total deviation in the number of glistenings for the 34 images in the training set. Using this threshold value, only slight agreement was found between automated software counts and manual expert counts for the validating set of 63 images (κ=0.104, 95%CI, 0.040-0.168). Ten images (15.9%) had glistenings counts that agreed between the software and manual counting. There were 49 images (77.8%) where the software overestimated the number of glistenings. CONCLUSION: The low levels of agreement show between an initial release of software used to automatically count glistenings in in vivo slit-lamp images and manual counting indicates that this is a non-trivial application. Iterative improvement involving a dialogue between software developers and experienced ophthalmologists is required to optimise agreement. The results suggest that validation of software is necessary for studies involving semi-automatic evaluation of glistenings.

20.
Korean J Ophthalmol ; 37(5): 401-408, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37621091

RESUMO

PURPOSE: To evaluate the usefulness of a newly generated monofocal intraocular lens (IOL) in patients with various retinal diseases who underwent combined cataract and pars plana vitrectomy surgery. METHODS: This prospective observational study included 33 patients with various retinal diseases. Monocular best-corrected distance visual acuity (BCDVA), uncorrected distance visual acuity (UCDVA), uncorrected intermediate visual acuity (UCIVA), uncorrected near visual acuity (UCNVA), and contrast sensitivity were measured and compared with 40 age-matched patients in the standard monofocal IOL. RESULTS: The Eyhance IOL group demonstrated significantly better UCIVA at 6 months follow-up compared to the standard monofocal IOL group. No significant differences were observed between the two groups in contrast sensitivity, BCDVA, UCDVA, or UCNVA. The regression analysis showed a significant association between preoperative corrected distance visual acuity and improved UCIVA in the Eyhance IOL group. CONCLUSIONS: The Eyhance ICB00 IOL proved to be a valuable option for patients with retinal diseases undergoing combined cataract surgery and vitrectomy. It effectively improved intermediate vision without compromising contrast sensitivity or distance visual acuity.

SELEÇÃO DE REFERÊNCIAS